Industrologic SS422

SMPT Slave RS-422 to RS-232 Converter for Industrologic products

Reference Manual

version 3/6/03



Industrologic, Inc.
3201 Highgate Lane
St. Charles, MO
63301
USA

Phone: (636) 723-4000
WWW: http://www.industrologic.com
Email: info@industrologic.com




Trademark and Copyright Information

SS422 is a Trademark of Industrologic, Inc. 2003

This document is Copyright (c) 2003 by Industrologic, Inc.
All rights reserved.

No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying or scanning, for any purpose other than the personal use by the purchaser of this product. Industrologic, Inc. reserves the right to revise this document at any time without obligation to notify any person of such revision. Industrologic, Inc. assumes no responsibility for any errors that may appear in this document.


Warning/Disclaimer

Whereas effort has been made to make the information in this document as useful and accurate as possible, Industrologic, Inc. assumes no responsibility for the application, usefulness, or completeness, of the information contained herein. Under no circumstance will Industrologic, Inc. be responsible or liable for any damages or losses including indirect or consequential damages or losses arising from either the use of any information contained within this manual or the use of any products or services referenced within this manual.

Industrologic, Inc. reserves the right to change any product's features, specifications, documentation, warranties, fee schedules, and conditions at any time and without notice.

Industrologic products are provided as printed circuit board level assemblies. Some Industrologic products may include mechanical packaging assessories which are provide for the purchaser's convenience, and are not intended to be final assembly enclosures.

Industrologic products are provided with the understanding that the purchaser will determine fitness for any particular application as well as achieve compliance with any particular specifications or regulations as required or desired for that application.


Warranty

Industrologic, Inc. products are warranted to be free from defects in workmanship or material under normal use and service for a period of one year from date of purchase. Industrologic's warranty is to the original purchaser only, but is extended to you by the Distributor or OEM from whom you purchased the product.

Industrologic's obligation under this Warranty is limited to replacement with a new or repaired unit to the original purchaser. The unit must be returned, and replacements obtained from Industrologic, Inc. or the Distributor or OEM from whom it was purchased.

This warranty will not apply if, in the judgment of Industrologic, Inc., damage or failure of the product has resulted from accident, alteration, misuse, abuse, connection to or operation with incompatible signals or power sources, or improper installation.

Under no circumstances shall Industrologic, Inc. be liable to purchaser or any third party for any loss of profits or other direct or indirect costs, expenses, losses, or consequential damages arising out of or as a result of any defects in or failure of Industrologic products or any part or parts thereof.

THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EITHER EXPRESSED OR IMPLIED, AS TO DESCRIPTION, QUALITY, MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR ANY OTHER MATTER.


Return and Repair Policy

Products purchased in single piece quantities may be returned, if in resellable condition, for a full refund of the purchase price only, to the original purchaser, within 30 days of purchase.

Products must be returned by original purchaser with a Return Materials Authorization (RMA) number issued by Industrologic, Inc. or the Distributor or OEM from whom it was purchased, authorizing its return. Current repair or replacement fees and procedures will be related during the issue of the RMA number.

Warranty or repair units must be returned with postage and insurance paid by purchaser. Industrologic, Inc. is not responsible for damages or loss during shipment.





Industrologic SS422

SMPT Slave RS-422 to RS-232 Converter for Industrologic products

The Industrologic SS422 is an RS-422 to RS-232 converter designed to enable Industrologic products with a "Slave to PC" type RS-232 connection to be driven by RS-422 as a SMPT Slave device.



picture of SS422


Summary of Features



Mechanical Specifications

.062" FR-4 glass epoxy printed circuit board


SS422 dimensions and connections



Electrical Specifications

Operating environment:
Temperature: 0-50 degrees Celsius (32-122 Fahrenheit)
Humidity: 30 to 80 percent, non-condensing

Power supply requirements:
Operating voltage: +5
Operating current: Up to 15mA
Power supply connector: Pin 9 of RS-232 connector

RS-232 Interface:
Pinout: Matches devices that connect pin-to-pin with PC DB9 serial port
Drivers: MAX232 or equivalent RS-232 transceiver

RS-422 Interface:
Pinout: Full-duplex SMPT "Slave"
Drivers: MAX 491 or equivalent RS-485/RS-422 transceiver
Termination: Optional 120 ohm resistor across receive signal



Using the SS422

RS-232 connection:

The male DB9 connector on the SS422 is designed to plug directly into the female DB9 connector on any Industrologic product or other device that has +5 volts power available on pin 9 of the connector. Some Industrologic products have jumpers associated with their serial ports that select whether pin 9 is connected to 5 volts, unregulated (+V), or nothing. If this choice exists, 5 volt option must be used. Do not use the unregulated (+V) option!

RS-422 connection:

The following drawing shows the pinout of the RS-422 signals on the female DB9 connector on the SS422 and how they should be connected to a SMPTE "Master" device. The ground connections shown are typically the shields (if they exist) present in the cable used to do the RS-422 wiring, and may not be necessary for all applications.


diagram of SS422 connections


A 120 ohm termination resistor is available to be connected across the receive input pins if required by the application. The plastic jumper plug at P1 should be set to "N" for no termination, or "T" to connect the termination resistor.



SS422 Schematic

schematic diagram of SS422



end of manual
log file